| Content Provider | The American Society of Mechanical Engineers (ASME) Digital Collection |
|---|---|
| Author | Naitoh, Masanori Suzuki, Hiroaki Okada, Hidetoshi |
| Copyright Year | 2012 |
| Abstract | The Tohoku Region Pacific Coast Earthquake with magnitude 9.0 occurred at 2:46 PM of March 11th, 2011, followed by a huge Tsunami. The Fukushima Daiichi nuclear power station suffered serious damages from the Tsunami, involving core melt and release of large amount of fission products to an environment. The station blackout (SBO) occurred due to submergence of emergency equipment by the sea water. The isolation condenser (IC) was the only device for decay heat removal at the unit-1 of the Fukushima Daiichi nuclear power station after the reactor scram. The IC function was analyzed with a severe accident analysis code SAMPSON. The analysis results showed that (1) core melt resulting in RPV failure occurred since the IC operation was limited because it was not designed as a countermeasure to mitigate severe accident progression in Japan and (2) even assuming the continuous IC operation after the SBO to mitigate severe accident progression, the RPV failure occurred at 18:52, March 12th. However, since the alternate water injection by a fire engine was actually ready to start at 5:46, March 12th, which was earlier than calculated RPV failure time, the RPV failure could be prevented by continuous IC operation. |
| Sponsorship | Nuclear Engineering Division Power Division |
| Starting Page | 819 |
| Ending Page | 824 |
| Page Count | 6 |
| File Format | |
| ISBN | 9780791844991 |
| DOI | 10.1115/ICONE20-POWER2012-55239 |
| Volume Number | Volume 5: Fusion Engineering; Student Paper Competition; Design Basis and Beyond Design Basis Events; Simple and Combined Cycles |
| Conference Proceedings | 2012 20th International Conference on Nuclear Engineering and the ASME 2012 Power Conference |
| Language | English |
| Publisher Date | 2012-07-30 |
| Publisher Place | Anaheim, California, USA |
| Access Restriction | Subscribed |
| Subject Keyword | Fukushima Core melt Sampson code Isolation condenser Severe accident 2011 Fukushima nuclear disaster Condensers (steam plant) Nuclear power stations Japan Accidents |
| Content Type | Text |
| Resource Type | Article |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|